Skip to content
Online sample submission is now open — get a reference number instantly and track your analysis. →

03 · PL

Ultra-sensitive emission studies down to trace levels

Records excitation and emission spectra of fluorescent molecules and materials — for sensing, quantum-dot and dye studies, quenching experiments and photophysical characterisation.

Live trace · illustrativePL
250350450550650ExcitationEmissionWavelength (nm)Intensity (a.u.)
Light source
Xenon lamp
Modes
Emission, excitation and synchronous scans; time scans

Working principle

A xenon lamp and an excitation monochromator select a wavelength that the sample absorbs. Excited molecules relax and emit light at longer wavelengths; this emission is collected at right angles to the excitation beam, passed through a second monochromator and measured by a sensitive photomultiplier detector.

Because emission is measured against a dark background, fluorescence is often a thousand times more sensitive than absorbance. Changes in intensity, wavelength or shape of the emission reveal binding events, the local environment, and energy or electron transfer.

250350450550650ExcitationEmissionWavelength (nm)Intensity (a.u.)

Representative spectrum · for illustration

Technical specifications

Light source
Xenon lamp
Modes
Emission, excitation and synchronous scans; time scans
Wavelength range
Approx. 200 – 900 nm (typical)
Geometry
90° detection, 10 mm quartz cuvette
Data formats
PDF report, CSV / ASCII

Typical turnaround: 3–5 working days after sample receipt

Capabilities

  • Emission and excitation spectra
  • Fluorescence quenching (Stern–Volmer) studies
  • Sensing and detection-limit studies
  • Relative quantum-yield estimation
  • Synchronous fluorescence

Samples accepted

  • Dilute solutions
  • Colloidal dispersions
  • Quantum / carbon dot suspensions

Sample requirements

  • Provide 3–5 mL of a dilute solution (absorbance below 0.1 at the excitation wavelength)
  • Mention the solvent and the expected excitation / emission region
  • Use spectroscopic-grade solvents where possible
  • Protect light-sensitive samples from light during transport

Applications

01

Chemical sensors

“Turn-on / turn-off” probes for metal ions, anions and explosives; detection-limit calculation.

02

Quantum dots & carbon dots

Emission tuning, excitation dependence and photostability of nanomaterials.

03

Bio-interactions

Binding of drugs and probes with proteins and DNA through quenching studies.

04

Photochemistry

Energy and electron-transfer studies in dyes, complexes and photocatalysts.

Service charges

Available on request

Charges depend on the technique, the number of samples and your user category (internal, academic or industry). Submit an enquiry and we will email you a quotation.

Ready when you are

Send us your sample details and get a reference number instantly.

Track every step online — from review and quotation to analysis and report.